Recombinant fragment within Human SMCHD1 aa 1800-2000.
Species Reactivity
Human
Validated Applications
WB, IHC-P
Target Molecular Weight
Predicted band size: 226 kDa
Positive Control
293T cell lysate, HepG2 cell lysate, HeLa cell lysate, U-87 MG cell lysate, U-2 OS cell lysate, human breast cancer tissue, human testis tissue, human tonsil tissue.
Conjugation
unconjugated
Clone Number
JE34-29
Product Features
Form
Liquid
Concentration
1 mg/mL.(The concentration of this product may be batch-dependent)
Lot Concentration Lookup
Storage Instructions
Shipped at 4℃. Store at +4℃ short term (1-2 weeks). Store at -20℃ long term.
Structural Maintenance of Chromosomes flexible Hinge Domain Containing 1 (SMCHD1) is a protein that in humans is encoded by the SMCHD1 gene. Mutations in SMCHD1 are causative for development of facioscapulohumeral muscular dystrophy type 2 (FSHD2) and Bosma arhinia microphthalmia syndrome (BAMS). Without maternal SMCHD1 in the egg cell, children bear with altered skeletal structures.
Background References
1. Gurzau AD et al. Relating SMCHD1 structure to its function in epigenetic silencing. Biochem Soc Trans. 2020 Aug
2. Gurzau AD et al. SMCHD1\'s ubiquitin-like domain is required for N-terminal dimerization and chromatin localization. Biochem J. 2021 Jul
Structural maintenance of chromosomes flexible hinge domain containing 1 antibody
Structural maintenance of chromosomes flexible hinge domain-containing protein 1 antibody
Images
Western blot analysis of SMCHD1 on different lysates with Rabbit anti-SMCHD1 antibody (HA722141) at 1/1,000 dilution.
Lane 1: 293T cell lysate Lane 2: HepG2 cell lysate Lane 3: HeLa cell lysate Lane 4: U-87 MG cell lysate Lane 5: U-2 OS cell lysate
Lysates/proteins at 20 µg/Lane.
Predicted band size: 226 kDa Observed band size: 226 kDa
Exposure time: 30 seconds; ECL: K1801;
4-20% SDS-PAGE gel.
Proteins were transferred to a PVDF membrane and blocked with 5% NFDM/TBST for 1 hour at room temperature. The primary antibody (HA722141) at 1/1,000 dilution was used in 5% NFDM/TBST at 4℃ overnight. Goat Anti-Rabbit IgG - HRP Secondary Antibody (HA1001) at 1/50,000 dilution was used for 1 hour at room temperature.
Immunohistochemical analysis of paraffin-embedded human breast cancer tissue with Rabbit anti-SMCHD1 antibody (HA722141) at 1/200 dilution.
The section was pre-treated using heat mediated antigen retrieval with sodium citrate buffer (pH 6.0) (high pressure) for 2 minutes. The tissues were blocked in 1% BSA for 20 minutes at room temperature, washed with ddH2O and PBS, and then probed with the primary antibody (HA722141) at 1/200 dilution for 1 hour at room temperature. The detection was performed using an HRP conjugated compact polymer system. DAB was used as the chromogen. Tissues were counterstained with hematoxylin and mounted with DPX.
Immunohistochemical analysis of paraffin-embedded human testis tissue with Rabbit anti-SMCHD1 antibody (HA722141) at 1/200 dilution.
The section was pre-treated using heat mediated antigen retrieval with sodium citrate buffer (pH 6.0) (high pressure) for 2 minutes. The tissues were blocked in 1% BSA for 20 minutes at room temperature, washed with ddH2O and PBS, and then probed with the primary antibody (HA722141) at 1/200 dilution for 1 hour at room temperature. The detection was performed using an HRP conjugated compact polymer system. DAB was used as the chromogen. Tissues were counterstained with hematoxylin and mounted with DPX.
Immunohistochemical analysis of paraffin-embedded human tonsil tissue with Rabbit anti-SMCHD1 antibody (HA722141) at 1/200 dilution.
The section was pre-treated using heat mediated antigen retrieval with sodium citrate buffer (pH 6.0) (high pressure) for 2 minutes. The tissues were blocked in 1% BSA for 20 minutes at room temperature, washed with ddH2O and PBS, and then probed with the primary antibody (HA722141) at 1/200 dilution for 1 hour at room temperature. The detection was performed using an HRP conjugated compact polymer system. DAB was used as the chromogen. Tissues were counterstained with hematoxylin and mounted with DPX.
Please note: All products are "FOR RESEARCH USE ONLY AND ARE NOT INTENDED FOR DIAGNOSTIC OR THERAPEUTIC USE"