Mouse PD-L1 enzyme-linked immunoassay kit
Usd: 499 Special Discount
Specification
Safety datasheet
Select your chosen country/region
- MSDS_HUABIO.pdf
- MSDS_HUABIO.pdf
- MSDS_EM0036_Europe.pdf
- No MSDS Found
Overview
Product Name
Mouse PD-L1 enzyme-linked immunoassay kit
Product Type
Elisa Kit
Sensitivity
0.16 pg/ml (10 μl)
| pg/ml | O.D. | Average | Corrected | |
|---|---|---|---|---|
| 0.00 | 0.0578 | 0.0568 | 0.0573 | |
| 1.37 | 0.0794 | 0.0801 | 0.0798 | 0.0225 |
| 4.12 | 0.1089 | 0.0990 | 0.1040 | 0.0467 |
| 12.35 | 0.1731 | 0.1708 | 0.1720 | 0.1147 |
| 37.04 | 0.3835 | 0.3865 | 0.3850 | 0.3277 |
| 111.11 | 0.9157 | 0.9152 | 0.9155 | 0.8582 |
| 333.33 | 2.1664 | 2.1622 | 2.1643 | 2.1070 |
| 1000.00 | 3.9609 | 3.9586 | 3.9598 | 3.9025 |
Precision
| Intra-assay Precision | Inter-assay Precision | |||||
| Sample Number | S1 | S2 | S3 | S1 | S2 | S3 |
| 22 | 22 | 22 | 6 | 6 | 6 | |
| Average (pg/ml) | 24.1 | 109.5 | 371.6 | 24.4 | 127.7 | 359.1 |
| Standard Deviation | 0.8 | 6.8 | 8.5 | 1.0 | 3.9 | 6.9 |
| Coefficient of Variation (%) | 3.3 | 6.2 | 2.3 | 4.0 | 3.1 | 1.9 |
Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.
Spike Recovery
The spike recovery was evaluated by spiking 3 levels of mouse PD-L1 into health mouse serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 86% to 116% with an overall mean recovery of 107%.
Sample Value
| Sample Matrix | Sample Evaluated | Range (pg/ml) | Detectable (%) | Mean of Detectable (pg/ml) |
|---|---|---|---|---|
| Serum | 30 | 122.17-529.36 | 100 | 341.58 |
Serum/Plasma – Thirty samples from apparently healthy mice were evaluated for the presence of CRP in this assay. No medical histories were available for the donors. n.d. = non-detectable. Samples measured below the sensitivity are considered to be non-detectable.
Experiment Type
Species Reactivity
Detection Method
Operation Duration
Standard Curve Gradient
Incubation Count
2
Detectable Sample
Dosing Volume
Product Features
Storage Condition
Store at 2-8 ℃
Target
UNIPROT
Alias
B7 H
B7 H1
B7 homolog 1
B7-H1
B7H
B7H1
CD 274
CD-274
CD274
CD274 antigen
CD274 molecule
MGC142294
MGC142296
OTTHUMP00000021029
PD L1
PD-L1
PD1L1_HUMAN
PDCD1 ligand 1
PDCD1L1
PDCD1LG1
PDL 1
PDL1
Programmed cell death 1 ligand 1
Programmed death ligand 1
RGD1566211
CollapseFunction
Same Target and Pathway Products