Human Galectin-9/LGALS9 enzyme-linked immunoassay kit
Usd: 499 Special Discount
Specification
Safety datasheet
Overview
Product Name
Human Galectin-9/LGALS9 enzyme-linked immunoassay kit
Product Type
Elisa Kit
Sensitivity
1.38pg/ml (50 μl);5.95pg/ml (10 μl);
| pg/ml | O.D. | Average | Corrected | |
|---|---|---|---|---|
| 0.00 | 0.0066 | 0.0059 | 0.0063 | |
| 13.72 | 0.0180 | 0.0140 | 0.0160 | 0.0098 |
| 41.15 | 0.0372 | 0.0314 | 0.0343 | 0.0281 |
| 123.46 | 0.0982 | 0.0935 | 0.0959 | 0.0896 |
| 370.37 | 0.2808 | 0.2398 | 0.2603 | 0.2541 |
| 1111.11 | 0.7660 | 0.6679 | 0.7170 | 0.7107 |
| 3333.33 | 1.9190 | 1.8850 | 1.9020 | 1.8958 |
| 10000.00 | 3.9880 | 3.9520 | 3.9700 | 3.9638 |
Precision
| Intra-assay Precision | Inter-assay Precision | |||||
| Sample Number | S1 | S2 | S3 | S1 | S2 | S3 |
| 22 | 22 | 22 | 6 | 6 | 6 | |
| Average (pg/ml) | 149.0 | 818.1 | 2827.2 | 157.3 | 855.1 | 3030.7 |
| Standard Deviation | 8.4 | 34.3 | 198.8 | 8.5 | 29.7 | 111.4 |
| Coefficient of Variation (%) | 5.6 | 4.2 | 7.0 | 5.4 | 3.5 | 3.7 |
Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty-two times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.
Spike Recovery
The spike recovery was evaluated by spiking 3 levels of human Galectin-9/LGALS9 into health human serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 85% to 114% with an overall mean recovery of 105%.
Sample Value
| Sample Matrix | Sample Evaluated | Range (ng/ml) | Detectable (%) | Mean of Detectable (ng/ml) |
|---|---|---|---|---|
| Serum | 30 | 5.86-22.04 | 100.0 | 12.35 |
Serum/Plasma – Thirty samples from apparently healthy volunteers were evaluated for the presence of human Galectin-9/LGALS9 in this assay. No medical histories were available for the donors. n.d. = non-detectable. Samples measured below the sensitivity are considered to be non-detectable.
Experiment Type
Species Reactivity
Detection Method
Operation Duration
Standard Curve Gradient
Incubation Count
2
Detectable Sample
Dosing Volume
Product Features
Storage Condition
Store at 2-8 ℃
Target
UNIPROT
Alias
36 kDa beta-galactoside-binding lectin antibody
Ecalectin antibody
Gal-9 antibody
galectin 9 antibody
Galectin-9 antibody
galectin9 antibody
HOM HD 21 antibody
HOMHD21 antibody
HUAT antibody
Lectin galactoside binding soluble 9 antibody
Expand36 kDa beta-galactoside-binding lectin antibody
Ecalectin antibody
Gal-9 antibody
galectin 9 antibody
Galectin-9 antibody
galectin9 antibody
HOM HD 21 antibody
HOMHD21 antibody
HUAT antibody
Lectin galactoside binding soluble 9 antibody
LEG9_HUMAN antibody
LGAL S9 antibody
LGALS 9 antibody
Lgals9 antibody
LGALS9A antibody
MGC117375 antibody
MGC125973 antibody
MGC125974 antibody
Tumor antigen HOM-HD-21 antibody
UAT antibody
Urate transporter/channel antibody
Urate transporter/channel protein antibody
CollapseFunction
Same Target and Pathway Products