Human LDLR/LDL Receptor enzyme-linked immunoassay kit(one step)
Usd: 619 Special Discount
Specification
Safety datasheet
Overview
Product Name
Human LDLR/LDL Receptor enzyme-linked immunoassay kit(one step)
Product Type
Elisa Kit
Sensitivity
0.03ng/ml (50 μl);0.29ng/ml (10 μl);
| ng/ml | O.D. | Average | Corrected | |
|---|---|---|---|---|
| 0.00 | 0.0160 | 0.0162 | 0.0161 | |
| 0.41 | 0.0279 | 0.0279 | 0.0279 | 0.0118 |
| 1.23 | 0.0534 | 0.0570 | 0.0552 | 0.0391 |
| 3.70 | 0.1377 | 0.1378 | 0.1378 | 0.1217 |
| 11.11 | 0.3575 | 0.3765 | 0.3670 | 0.3509 |
| 33.33 | 0.9658 | 1.0070 | 0.9864 | 0.9703 |
| 100.00 | 2.1840 | 2.2330 | 2.2085 | 2.1924 |
| 300.00 | 3.5340 | 3.6290 | 3.5815 | 3.5654 |
Precision
| Intra-assay Precision | Inter-assay Precision | |||||
| Sample Number | S1 | S2 | S3 | S1 | S2 | S3 |
| 22 | 22 | 22 | 6 | 6 | 6 | |
| Average (ng/ml) | 75.9 | 160.5 | 278.5 | 79.8 | 151.0 | 245.6 |
| Standard Deviation | 5.8 | 12.1 | 21.5 | 4.6 | 9.1 | 16.9 |
| Coefficient of Variation (%) | 7.6 | 7.6 | 7.7 | 5.7 | 6.0 | 6.9 |
Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty-two times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.
Spike Recovery
The spike recovery was evaluated by spiking 3 levels of Human LDLR/LDL Receptor into health human serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 80% to 115% with an overall mean recovery of 105%.
Sample Value
| Sample Matrix | Sample Evaluated | Range (ng/ml) | Detectable (%) | Mean of Detectable (ng/ml) |
|---|---|---|---|---|
| Serum | 30 | 2.56-21.69 | 100 | 6.46 |
Serum/Plasma – Thirty samples from apparently healthy volunteers were evaluated for the presence of Human LDLR/LDL Receptor in this assay. No medical histories were available for the donors. n.d. = non-detectable. Samples measured below the sensitivity are considered to be non-detectable.
Experiment Type
Species Reactivity
Detection Method
Operation Duration
Standard Curve Gradient
Incubation Count
1
Detectable Sample
Dosing Volume
Product Features
Storage Condition
Store at 2-8 ℃
Target
UNIPROT
Alias
FH
FHC
LDL R
LDL receptor
LDLCQ2
Ldlr
LDLR_HUMAN
Low Density Lipoprotein Receptor
Low density lipoprotein receptor class A domain containing protein 3
Low density lipoprotein receptor familial hypercholesterolemia
ExpandFH
FHC
LDL R
LDL receptor
LDLCQ2
Ldlr
LDLR_HUMAN
Low Density Lipoprotein Receptor
Low density lipoprotein receptor class A domain containing protein 3
Low density lipoprotein receptor familial hypercholesterolemia
Low-density lipoprotein receptor
LDLRLDLReceptor
CollapseFunction
Products with the Same Target and Pathway