Human GC/ Vitamin D binding protein enzyme-linked immunoassay kit(one step)
Usd: 619 Special Discount
Specification
Safety datasheet
Overview
Product Name
Human GC/ Vitamin D binding protein enzyme-linked immunoassay kit(one step)
Product Type
Elisa Kit
Sensitivity
0.02ng/ml (10 μl);
| ng/ml | O.D. | Average | Corrected | |
|---|---|---|---|---|
| 0.00 | 0.0071 | 0.0067 | 0.0069 | |
| 3.13 | 0.0950 | 0.0898 | 0.0924 | 0.0855 |
| 6.25 | 0.2007 | 0.2054 | 0.2031 | 0.1962 |
| 12.50 | 0.4132 | 0.4261 | 0.4197 | 0.4128 |
| 25.00 | 0.7953 | 0.8747 | 0.8350 | 0.8281 |
| 50.00 | 1.4820 | 1.5430 | 1.5125 | 1.5056 |
| 100.00 | 2.3330 | 2.2810 | 2.3070 | 2.3001 |
| 200.00 | 3.2110 | 3.2380 | 3.2245 | 3.2176 |
Precision
| Intra-assay Precision | Inter-assay Precision | |||||
| Sample Number | S1 | S2 | S3 | S1 | S2 | S3 |
| 22 | 22 | 22 | 6 | 6 | 6 | |
| Average (ng/ml) | 4.1 | 22.3 | 66.0 | 5.7 | 22.3 | 57.7 |
| Standard Deviation | 0.2 | 1.0 | 3.5 | 0.2 | 0.8 | 1.5 |
| Coefficient of Variation (%) | 5.2 | 4.7 | 5.3 | 3.5 | 3.5 | 2.7 |
Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty-two times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.
Spike Recovery
The spike recovery was evaluated by spiking 3 levels of human GC/Vitamin D binding protein into health human serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 99% to 120% with an overall mean recovery of 110%.
Sample Value
| Sample Matrix | Sample Evaluated | Range (μg/ml) | Detectable (%) | Mean of Detectable (μg/ml) |
|---|---|---|---|---|
| Serum | 30 | 272.48-1100.54 | 100 | 654.69 |
Serum/Plasma – Thirty samples from apparently healthy volunteers were evaluated for the presence of human GC/Vitamin D binding protein in this assay. No medical histories were available for the donors.n.d. = non-detectable. Samples measured below the sensitivity are considered to be non-detectable.
Experiment Type
Species Reactivity
Detection Method
Operation Duration
Standard Curve Gradient
Incubation Count
1
Detectable Sample
Dosing Volume
Product Features
Storage Condition
Store at 2-8 ℃
Target
UNIPROT
Alias
DBP
DBP/GC
GC
Gc globulin
Gc-globulin
GRD3
Group specific component
Group specific component vitamin D binding protein
Group-specific component
hDBP
ExpandDBP
DBP/GC
GC
Gc globulin
Gc-globulin
GRD3
Group specific component
Group specific component vitamin D binding protein
Group-specific component
hDBP
VDB
VDBG
VDBP
Vitamin D binding alpha globulin
Vitamin D-binding protein
VTDB_HUMAN
GCVitaminDbindingprotein
CollapseProducts with the Same Target and Pathway