Human/Mouse C-Fos enzyme-linked immunoassay kit
Usd: 499 Special Discount
Specification
Safety datasheet
Overview
Product Name
Human/Mouse C-Fos enzyme-linked immunoassay kit
Product Type
Elisa Kit
Sensitivity
0.42 pg/ml (50 μl);0.92 pg/ml (10 μl);
| pg/ml | O.D. | Average | Corrected | |
|---|---|---|---|---|
| 0.00 | 0.0137 | 0.0147 | 0.0142 | |
| 1.37 | 0.0205 | 0.0195 | 0.0200 | 0.0058 |
| 4.12 | 0.0329 | 0.0322 | 0.0326 | 0.0183 |
| 12.35 | 0.0713 | 0.0742 | 0.0728 | 0.0585 |
| 37.04 | 0.2012 | 0.1856 | 0.1934 | 0.1792 |
| 111.11 | 0.5080 | 0.5080 | 0.5080 | 0.4938 |
| 333.33 | 1.3790 | 1.3730 | 1.3760 | 1.3618 |
| 1000.00 | 3.4090 | 3.2950 | 3.3520 | 3.3378 |
Precision
| Intra-assay Precision | Inter-assay Precision | |||||
| Sample Number | S1 | S2 | S3 | S1 | S2 | S3 |
| 22 | 22 | 22 | 6 | 6 | 6 | |
| Average (pg/ml) | 24.1 | 112.9 | 337.4 | 23.8 | 115.5 | 326.8 |
| Standard Deviation | 0.7 | 3.8 | 8.7 | 0.3 | 4.0 | 11.7 |
| Coefficient of Variation (%) | 3.0 | 3.4 | 2.6 | 1.1 | 3.5 | 3.6 |
Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty-two times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.
Spike Recovery
The spike recovery was evaluated by spiking 3 levels of human/mouse C-Fos into health human/mouse serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 93% to 116% with an overall mean recovery of102%.
Sample Value
| Sample Matrix | Sample Evaluated | Range (pg/ml) | Detectable (%) | Mean of Detectable (pg/ml) |
|---|---|---|---|---|
| Human serum | 30 | 0.48-14.65 | 100 | 5.28 |
| Mouse serum | 30 | 0.19-121.65 | 100 | 9.33 |
Serum/Plasma – Thirty samples from apparently healthy volunteers and thirty samples from apparently healthy mice were evaluated for the presence of human/mouse C-Fos in this assay. No medical histories were available for the donors. n.d. = non-detectable. Samples measured below the sensitivity are considered to be non-detectable.
Experiment Type
Species Reactivity
Detection Method
Operation Duration
Standard Curve Gradient
Incubation Count
2
Detectable Sample
Dosing Volume
Product Features
Storage Condition
Store at 2-8 ℃
Target
Alias
Activator protein 1
AP 1
C FOS
Cellular oncogene c fos
Cellular oncogene fos
FBJ murine osteosarcoma viral (v fos) oncogene homolog (oncogene FOS)
FBJ murine osteosarcoma viral oncogene homolog
FBJ murine osteosarcoma viral v fos oncogene homolog
FBJ Osteosarcoma Virus
FOS
ExpandActivator protein 1
AP 1
C FOS
Cellular oncogene c fos
Cellular oncogene fos
FBJ murine osteosarcoma viral (v fos) oncogene homolog (oncogene FOS)
FBJ murine osteosarcoma viral oncogene homolog
FBJ murine osteosarcoma viral v fos oncogene homolog
FBJ Osteosarcoma Virus
FOS
FOS protein
FOS_HUMAN
G0 G1 switch regulatory protein 7
G0/G1 switch regulatory protein 7
G0S7
Oncogene FOS
p55
proto oncogene c Fos
Proto oncogene protein c fos
Proto-oncogene c-Fos
v fos FBJ murine osteosarcoma viral oncogene homolog
CollapseFunction