Human MUC6/Mucin-6 enzyme-linked immunoassay kit
Usd: 499 Special Discount
Specification
Safety datasheet
Overview
Product Name
Human MUC6/Mucin-6 enzyme-linked immunoassay kit
Product Type
Elisa Kit
Sensitivity
0.31pg/ml (50 μl);3.33pg/ml (10 μl);
| pg/ml | O.D. | Average | Corrected | |
|---|---|---|---|---|
| 0.00 | 0.0057 | 0.0057 | 0.0057 | |
| 4.12 | 0.0100 | 0.0094 | 0.0097 | 0.0040 |
| 12.35 | 0.0209 | 0.0196 | 0.0203 | 0.0146 |
| 37.04 | 0.0598 | 0.0585 | 0.0592 | 0.0535 |
| 111.11 | 0.1701 | 0.1647 | 0.1674 | 0.1617 |
| 333.33 | 0.4992 | 0.4846 | 0.4919 | 0.4862 |
| 1000.00 | 1.3210 | 1.3120 | 1.3165 | 1.3108 |
| 3000.00 | 2.6780 | 2.6400 | 2.6590 | 2.6533 |
Precision
| Intra-assay Precision | Inter-assay Precision | |||||
| Sample Number | S1 | S2 | S3 | S1 | S2 | S3 |
| 22 | 22 | 22 | 6 | 6 | 6 | |
| Average (pg/ml) | 39.8 | 263.0 | 850.8 | 42.6 | 264.9 | 868.6 |
| Standard Deviation | 2.1 | 11.1 | 54.5 | 2.2 | 13.2 | 30.8 |
| Coefficient of Variation (%) | 5.2 | 4.2 | 6.4 | 5.2 | 5.0 | 3.5 |
Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty-two times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.
Spike Recovery
The spike recovery was evaluated by spiking 3 levels of human MUC6/Mucin-6 into health human serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 78% to 112% with an overall mean recovery of 96%.
Sample Value
| Sample Matrix | Sample Evaluated | Range (pg/ml) | Detectable (%) | Mean of Detectable (pg/ml) |
|---|---|---|---|---|
| Serum | 30 | n.d. | 0 | n.d. |
Serum/Plasma – Thirty samples from apparently healthy volunteers were evaluated for the presence of human MUC6/Mucin-6 in this assay. No medical histories were available for the donors. n.d. = non-detectable. Samples measured below the sensitivity are considered to be non-detectable.
Experiment Type
Species Reactivity
Detection Method
Operation Duration
Standard Curve Gradient
Incubation Count
2
Detectable Sample
Dosing Volume
Product Features
Storage Condition
Store at 2-8 ℃
Target
UNIPROT
Alias
Mucin-6
MUC-6
Gastric mucin-6
MUC6
MUC6Mucin6
Function
Products with the Same Target and Pathway